EQUIPMENT
The Loctite® AssureCure™ Monitoring System is designed to detect, measure, analyze, record and provide a degree of cure metric relative to the transition of specially formulated adhesives from a liquid to a solid (cured).

Visit equipment.loctite.com for the complete line of Loctite® dispensing and curing equipment.
The AssureCure™ system includes the following components:
![]() |
![]() |
![]() |
| interface module/ LIGHT SOURCE Illuminates the adhesive bond line. Light must reach the bond line directly or through light transmissible materials. |
DETECTION SYSTEM Optically measures the adhesive's response which changes during the polymerization process. One to four points possible. |
SOFTWARE Analyzes data and provides a quantifiable output directly related to the progress of the curing reaction. Output signal to user-supplied PC or PLC can be configured to yield a go/no-go status or a numerical value directly related to the level of cure achieved. |
| System Component | Function | Part Number |
| Interface Module with LED Light Source | Measures, analyzes and records multiple optical measurements | 1470727 |
| Light Source Fiber | Transmits light to adhesive bond line (up to 4 points) |
Single - 1470724 |
| Double - 1470728 | ||
| Triple - 1470729 | ||
| Quad - 1470730 | ||
| Detector Fiber | Directs adhesive's optical response to Optic Module |
1470771 |
| Optic Module | Analyzes multiple optical measurements | 1471134 |
| Optic Processor | Accepts input from multiple optic modules and provides output to PC/PLC | 1470726 |